NOTE: Upon entry into the following 3 Delayed
Violation Modes, the red LED flash and the Au-
dible Alarm will sound, even if Set OFF. When
these events occur, the Alarm cannot be ac-
knowledged (silenced) by pressing the A button.
NORM DELAYED VIOLATION #1
(Fig. 80)
If you remain above the Required Ceiling Stop Depth for more
than 5 minutes, the full TLBG and DOWN Arrow will flash until
you descend below the Required Stop Depth. The graphic
message DOWN > TO > xxF (or xxM) will continue to scroll.
> This is a continuation of a Conditional Violation.
NORM DELAYED VIOLATION #2
(Fig. 81)
The VT3 cannot calculate Decompression times for Stop Depths
much greater than 60 FT (18 M) and offers no indication of how
much time spent underwater would result in the need for a
greater Stop Depth.
If the Decompression obligation requires a Ceiling Stop Depth
between 60 FT (18 M) and 70 FT (21 M), the TLBG will flash
and the graphic message DECO > STOP > 60F (18M) will scroll
at the top of the display.
Fig. 81 - NORM DELAYED
VIOLATION #2 MAIN
Fig. 80 - NORM DELAYED