6 - 9
6 Drive Programming Commands
Drive Programming User’s Manual (I580-E2)
6-3 Command List
6
*1. The “rtcset” command is provided only for the 3G3RX Series Inverter.
The 3G3MX2 Series Inverters cannot use the “rtcset” command because they do not connect with the LCD Digital Oper-
ator (Model: 3G3AX-OP05).
Parameter Control Commands
Command Argument 1 Argument 2 Argument 3 Argument 4 Argument 5 Description
ChgParam
<parameter>
:
<variable/
constant>
Replaces the content
of <parameter> with
<variable/constant>.
MonParam <variable> :
<parameter>
Assigns the content of
<parameter> to
<variable>.
eepwrt Issues a request for
writing to the inverter's
EEPROM when the
following parameter
writing command is
executed (only once).
ChgParam
<parameter>
:
<variable/
constant>
Replaces the content of
<parameter> with <vari-
able/constant> and
save it in the EEPROM
simultaneously.
rtcset
*1
on/off <variable>
Assigns clock informa-
tion of the LCD Digital
Operator to <variable>.
Inverter Control Commands
Command Argument 1 Argument 2 Argument 3 Argument 4 Argument 5 Description
FW : 1
Operates the inverter
in the forward direction.
RV : 1
Operates the inverter
in the reverse direction.
stop Decelerates the
inverter to a stop.
Note: This command
acts as a reset when the
inverter is in a trip state.
trip
<variable/
constant>
Issues a user trip
according to <variable/
constant>.
SET-Freq :
<variable/
constant>
Assigns <variable/con-
stant> (0.01 Hz) to
the inverter frequency
reference variable.
ACCEL :
<variable/
constant>
Assigns <variable/con-
stant> (10 ms) to the
inverter acceleration
time variable.
DECEL :
<variable/
constant>
Assigns <variable/con-
stant> (10 ms) to the
inverter deceleration
time variable.