2 Specifications
2 - 4
Drive Programming User’s Manual (I580-E2)
Function variable Multi-function output
variable
The function options of the Multi-function Output P1 Selection (C021) for the
inverter are available.
MX2 and RX:
RUN, FA1, FA2, OL, OD, AL, FA3, OTQ, UV, TRQ, RNT, ONT, THM, BRK,
BER, ZS, DSE, POK, FA4, FA5, OL2, ODc, OIDc, FBV, NDc, LOG1, LOG2,
LOG3, WAC, WAF, FR, OHF, LOC, IRDY, FWR, RVR, MJA, WCO, and
WCOI
MX2 only:
FREF, REF, SETM, and EDM
RX only:
IP, O2Dc, LOG4, LOG5, LOG6, and WCO2
Input terminal variable MX2: X(00) to X(07)/8 points
Note: X(07) is for the Pulse Train Input RP Selection (enabled only
when P003 02)
RX: X(00) to X(07)/8 points
Output terminal vari-
able
MX2: Y(00) to Y(02)/3 points
RX: Y(00) to Y(05)/6 points
Internal user contact UB(0) to UB(7)/8 points
Timer output contact TD(0) to TD(7)/8 points
Timer counter variable TC(0) to TC(7)/8 points
Analog input terminal
variable
MX2: XA(0) and XA(1)
RX: XA(0) to XA(2)
Analog output termi-
nal variable
MX2: YA(0) and YA(1)
RX: YA(0) to YA(2)
Item Specifications