6 - 5
6 Drive Programming Commands
Drive Programming User’s Manual (I580-E2)
6-3 Command List
6
Additional Information
For the format of <condition>, refer to Conditions on page 6-6.
select <condition
variable>
Executes the com-
mands after the “case”
command when <con-
dition variable> is equal
to <condition value>.
case <condition
value 1>
Starts the commands
assigned to the condi-
tion value.
<command set 1> The command set
assigned to <condi-
tion value 1>
[“case” condition value n]
[<command set n>]
You can set one or
more conditions with
“case”.
case else Starts the commands
assigned to the values
other than the condi-
tion value.
<command set> The command set
assigned to the values
other than <condition
value>
end select
Ends the “case” syntax.
for <variable> <start value> <end value> <incremental
value>
Starts a loop from
<start value> until
<end value> with
<incremental value>.
<command set> The command set that
is executed repeatedly
next Goes to “for” (loop).
while <condition> Executes <command
set> while the <condi-
tion> is met.
<command set> The command set that
is executed while
<condition> is met.
wend Goes to “while” (loop).
until <condition> Executes <command
set> until <condition>
is met.
<command set> The command set that
is executed while
<condition> is not met.
loop Goes to “until” (loop).
wait <wait time> <wait time>
Waits for (wait time
0.01) seconds.
wait <condition> Waits until <condi-
tion> is met.
Command Argument 1 Argument 2 Argument 3 Argument 4 Argument 5 Description

Table of Contents

Other manuals for Omron 3G3MX2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3MX2 Series and is the answer not in the manual?

Omron 3G3MX2 Series Specifications

General IconGeneral
Frequency Range0.1 to 400 Hz
Control MethodV/f Control, Sensorless Vector Control
Overload Capacity150% for 60 seconds
Safety StandardCE, UL, cUL
IP RatingIP20
Output Voltage3-phase 200-240V AC
Output Frequency0.1 to 400 Hz
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground fault, Short circuit
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000 m
Braking UnitBuilt-in
CommunicationModbus RTU
Communication InterfaceRS-485
Cooling MethodForced air cooling
Enclosure RatingIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload