3 Operation Procedure for Drive Programming
3 - 6
Drive Programming User’s Manual (I580-E2)
Use FW (forward) and RV (reverse) variables to control RUN commands through the Drive Programming
program. Be sure to set the RUN Command Selection (A002/A202) to 01 (Control circuit terminal block)
when you use FW or RV variable.
You can control through the program regardless of the setting 00 (FW: Forward) (for MX2 only) or 01
(RV: Reverse) in Multi-function Input Selection.
The relationship between the following items is OR:
MX2: The program's RUN command and the multi-function input terminal set to 00 (FW: Forward).
RX: The program's RUN command and the forward RUN command terminal FW and the multi-function
input terminal set to 01 (RV: Reverse).
MX2:
RX:
Forward RUN command : the forward RUN command terminal FW (the relationship between the pro-
gram's RUN command and the RUN command via the control circuit terminal block is OR.)
RUN Command Selection Setting
Parameter
No.
Function name Data Description
A002/
A202
1st/2nd RUN Com-
mand Selection
01: Control circuit terminal
block
(Drive Programming)
Select 01 (Control circuit terminal block) to
control the RUN command through the pro-
gram with FW or RV variable.
If you select other setting, FW and RV vari-
able are disabled.
02: Digital Operator
03: Modbus communication
04: Option 1
05: Option 2
C001 to
C007
Multi-function Input
S1 to S7 Selection
00: FW (Forward) The relationship between the program's
RUN command and the RUN command via
the control circuit terminal block is OR.
01: RV (Reverse)
Parameter
No.
Function name Data Description
A002 RUN Command
Selection
01: Control circuit terminal
block
(Drive Programming)
Select 01 (Control circuit terminal block) to
control the RUN command through the pro-
gram with FW or RV variable.
If you select other setting, FW and RV vari-
able are disabled.
02: Digital Operator
03: Modbus communication
04: Option 1
05: Option 2
C001 to
C008
Multi-function Input
S1 to S8 Selection
01: RV (Reverse) The relationship between the program's
RUN command and the RUN command via
the control circuit terminal block is OR.