4 - 29
4 Drive Programming Editor
Drive Programming User’s Manual (I580-E2)
4-11 Other Useful Functions
4
Find and replace functions are only available in text programs. You can look for or replace any charac-
ter strings inside the text program by using the find and replace functions.
To use the Find function, click icon or press the shortcut keys Ctrl F and select [Find] tab.
To use the Replace function, click icon or press the shortcut keys Ctrl F and select [Replace] tab.
You can add comments to text tasks or subroutines. You cannot add comments to flowchart programs.
To add a comment in a text line, type the comment after putting a ' (single quote) mark. Comments are
displayed in green.
Example
Precautions for Correct Use
The comments created in a text program are deleted when the program is transferred (down-
loaded) to the inverter or compiled for program conversion. To save the created comments,
save the program before you execute program compilation. You can save the program by
saving the whole project in the CX-Drive or export file of the program.
In the verification process, the "program after compilation" is compared with the program
inside the inverter. Therefore, the comments, alias definitions, region definitions, etc. are not
verified.
Find and Replace Functions
Adding Comments (Text Program)
Find Replace

Table of Contents

Other manuals for Omron 3G3MX2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3MX2 Series and is the answer not in the manual?

Omron 3G3MX2 Series Specifications

General IconGeneral
Frequency Range0.1 to 400 Hz
Control MethodV/f Control, Sensorless Vector Control
Overload Capacity150% for 60 seconds
Safety StandardCE, UL, cUL
IP RatingIP20
Output Voltage3-phase 200-240V AC
Output Frequency0.1 to 400 Hz
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground fault, Short circuit
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000 m
Braking UnitBuilt-in
CommunicationModbus RTU
Communication InterfaceRS-485
Cooling MethodForced air cooling
Enclosure RatingIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload