EasyManua.ls Logo

Omron 3G3MX2 Series - Page 83

Omron 3G3MX2 Series
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Drive Programming User Variables
5 - 4
Drive Programming User’s Manual (I580-E2)
The internal user contact (word access) UBw is a function to use the internal user contacts UB(0) to
UB(7) as a word-size variable.
The internal user contacts UB(0) to UB(7) are set in the lower byte. For the upper byte data, zero is
read out. If any data is written to the upper byte, the data is ignored.
Precautions for Correct Use
When the Drive Programming program is stopped, the data of internal user contacts before the
program stop is retained. When the program execution is started again, the process begins with
the retained data.
Function
variable
Description Data range
Default
data
Unit Data size R/W
UBw Internal user contact
(word access)
0 to 255 0 Unsigned
1 word
R/W
Bit 8 to 15 7 6 5 4 3 2 1 0
Function Not used UB(7) UB(6) UB(5) UB(4) UB(3) UB(2) UB(1) UB(0)

Table of Contents

Other manuals for Omron 3G3MX2 Series

Related product manuals