EasyManua.ls Logo

Omron CJ - PROGRAMMING MANUAL 12-2009 - Debugging Instructions

Omron CJ - PROGRAMMING MANUAL 12-2009
448 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
148
Debugging Instructions
Section 3-27
3-27 Debugging Instructions
HOURS TO
SECONDS
SEC
@SEC
065
Output
Required
SECONDS TO
HOURS
HMS
@HMS
066
Output
Required
CLOCK
ADJUSTMENT
DATE
@DATE
735
Output
Required
Instruction
Mnemonic
Code
Symbol/Operand Function Location
Execution condition
TRACE
MEMORY
SAMPLING
TRSM
045
When TRSM(045) is executed, the status of a preselected bit or word
is sampled and stored in Trace Memory. TRSM(045) can be used any-
where in the program, any number of times.
Output
Not required
Instruction
Mnemonic
Code
Symbol/Operand Function Location
Execution condition
SEC(065)
S
D
S: 1st source
word
D: 1st destination
word
Hours
Seconds
Converts time data in hours/minutes/seconds format to an equivalent
time in seconds only.
Minutes
Seconds
HMS(066)
S
D
S: 1st source
word
D: 1st destination
word
Hours
Seconds
Minutes Seconds
Converts seconds data to an equivalent time in
hours/minutes/seconds format.
S
DATE(735)
S: 1st source
word
CPU Unit
Internal clock
Changes the internal clock setting to the setting in the specified
source words.
New
setting
Minutes
Day
Year
00
Seconds
Hour
Month
Day of week
TRSM(045)

Table of Contents

Related product manuals