EasyManua.ls Logo

Omron S8AS - User Manual

Omron S8AS
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
S8AS
Smart Power Supply
USER'S MANUAL
Cat. No. Z269-E1-05

Table of Contents

Questions and Answers

  • K
    Kerry McgeeSep 10, 2025
    Why isn't the desired parameter displayed on my Omron Power Supply S8AS?
    • S
      Susan ArnoldSep 10, 2025
      If the desired parameter is not being displayed on the Omron Power Supply S8AS, it may be because the setting is not allowed in the present protection level. Change the protection level setting.
  • G
    George SingletonSep 12, 2025
    Why can't I clear the overheating alarm on my Omron Power Supply S8AS?
    • K
      Kayla RiceSep 12, 2025
      If the overheating alarm (A23/ HOT alternating display) cannot be cleared on your Omron Power Supply S8AS, it is because if the S8AS stays overheated for more than 3 hours, the overheat alarm cannot be cleared because the life span of the Power Supply can no longer be calculated correctly. If the overheating alarm is displayed, be sure it is cleared within 3 hours.
  • R
    Robert JacksonSep 14, 2025
    Why is the temperature displayed on my Omron Power Supply S8AS different from the room temperature?
    • J
      Jason PorterSep 14, 2025
      If the displayed temperature on your Omron Power Supply S8AS is clearly different from the ambient temperature, it's because the S8AS detects its internal temperature, which can be 10 to 20°C higher than the ambient temperature. If the over-temperature output is being used to control a fan or cooling equipment, set the over-temperature output threshold based on the graph on page 37.
  • A
    Angela BruceSep 16, 2025
    Why does my Omron Power Supply S8AS display '---' for peak output current?
    • K
      Kevin FullerSep 16, 2025
      If the peak output current is not displayed on your Omron Power Supply S8AS and the display shows “- - -,” it is possible that the current may have exceeded the measurable range. Clear the peak output current in Run Mode.

Summary

SECTION 1 Features and Functions

SECTION 2 Specifications and Functions

2-3 Specifications

Lists detailed electrical and environmental ratings, characteristics, and performance specifications for S8AS models.

2-4 Basic Function Details

Explains key functions such as voltage monitoring, over-current protection, maintenance forecast, and over-temperature output.

SECTION 3 Installation and Wiring

3-1 Installing the S8 AS

Provides precautions and guidelines for selecting an installation site and installing the S8AS.

3-2 Installation

Covers mounting the S8AS in a panel using a DIN Rail and provides dimensional information.

3-3 Power Supply and Input;Output Wiring

Details wiring precautions, wire selection, and connection procedures for power and I/O terminals.

SECTION 4 Parameter Settings

4-1 Parameter Table

Presents a comprehensive table of all S8AS parameters, their settings, default values, and access levels.

4-5 Individual Branch Output Settings

Details how to set individual branch output parameters like current tripping threshold and type.

SECTION 5 Trial Operation to Actual Operation

5-4 Run Mode

Covers operating the S8AS in Run Mode, monitoring parameters, and clearing peak output currents.

SECTION 7 Error Processing

7-1 Troubleshooting

Offers a table of common observed problems, their possible causes, and remedies.

7-2 Seven-segment Error Codes

Lists all seven-segment display error codes, their meanings, and probable causes/remedies.

7-3 Clearing Errors

Explains methods for clearing errors, including using the Reset Key and power cycling.

Omron S8AS Specifications

General IconGeneral
BrandOmron
ModelS8AS
CategoryPower Supply
LanguageEnglish

Related product manuals