Flow and Energy Measurement
F-4300F-4300
Clamp-on Ultrasonic Flow MeterClamp-on Ultrasonic Flow Meter
Installation & Operation GuideInstallation & Operation Guide
DOC-0003010 Rev.F

Table of Contents

Other manuals for Onicon F-4300

Questions and Answers

  • A
    Ashley RomeroSep 12, 2025
    What to do if Onicon Measuring Instruments show empty or partially filled pipe?
    • E
      Edward SextonSep 12, 2025
      To ensure proper function of your Onicon Measuring Instruments, the pipe must be fluid-filled and acoustically transparent to obtain echoes.
  • M
    mclaughlintammySep 13, 2025
    What to do if Onicon Measuring Instruments show pipe not full?
    • M
      Marcia BryantSep 13, 2025
      To address a 'Pipe not full' error on your Onicon Measuring Instruments, verify the pipe is full by mounting the sensors at the top of the pipe and checking the echo icon. Note that no echo will be present if the pipe is not full.
  • A
    Ashley MoodySep 15, 2025
    What to do if coupling compound washed out or sensor loose on Onicon Measuring Instruments?
    • S
      sbrownSep 15, 2025
      If the coupling compound has washed out or a sensor is loose on the pipe of your Onicon Measuring Instruments, remount the sensor and use acoustic coupling compound ultrasonic couplant.

Summary

Safety Information and Precautions

General Safety Precautions

Essential safety measures for product installation, operation, and service.

General Information and Specifications

F-4300 Specifications

Lists key features, specifications, and technical data for the F-4300 transmitter and sensors.

Model Numbering System

Decodes the F-4300 model number to understand its configuration and options.

Installation Procedures

Site Selection Guidelines

Criteria for choosing an optimal installation location for the meter enclosure and transducers.

Mechanical Installation Details

Covers enclosure and transducer dimensions, and installation steps for 10, 20, and 30 Series.

Electrical Installation and Power

Covers input power, wiring diagrams, and electrical safety precautions.

Start-Up and Operation

Programming Menu Configuration

Guides through configuring units, setup, calibration, relays, logging, and communication.

BACnet MS;TP Communication

Modbus Communication Protocols

Modbus Register Map

Comprehensive table of Modbus register addresses, descriptions, and types for data access.

Commissioning and Field Verification

Step-by-Step Commissioning

Detailed procedure for verifying installation and operational parameters before final use.

Commissioning Measurement Worksheet

A checklist for recording essential installation and operational data during commissioning.

Troubleshooting Common Issues

Troubleshooting Meter Readings

Solutions for common problems like erratic, low, or high meter readings.

Troubleshooting No Echo Signal

Steps to resolve issues when the meter does not detect a signal from the transducers.

Onicon F-4300 Specifications

General IconGeneral
TypeElectromagnetic Flow Meter
Enclosure RatingNEMA 4X (IP66)
Probe Material316 Stainless Steel
Insertion LengthAdjustable
Outputs4-20 mA, Pulse, Modbus RTU