Automated Acquisition mode can be stopped by tapping the Cancel button on the
right side of the Automated Acquisition job tile in the Jobs tab. Automated
Acquisition job setup does not persist over a power cycle.
4.3.5 Duplication over a network
The 10–gigabit Ethernet interface of TX1 enables superior network imaging performance
when combined with a properly configured 10–gigabit network infrastructure setup and
destination storage server such as a Storage Area Network (SAN) or Network Attached
Storage (NAS) or a Windows or Linux server configured with an iSCSI target or CIFS
share. Duplication/Logical Imaging *from* network-based iSCSI targets and CIFS shares
is also supported.
Note: TX1 must be connected to a network before attempting to mount and use iSCSI
targets or CIFS shares.
4.3.5.1 Adding an iSCSI target
1. To add an iSCSI target as a source or destination drive, tap the Sources or
Destinations button at the bottom of the Home screen. Then tap the orange plus
button in the upper right corner of the drive list and tap Mount iSCSI Target to
display the iSCSI Discovery screen.
Copyright © 2022 Open Text. All rights reserved. Trademarks owned by Open Text.