Home
OPTi
Measuring Instruments
CCA-TS2
OPTi CCA-TS2 User Manual
4
of 1
of 1 rating
299 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
OPTI
™
CCA-TS2
Analyzer
Operator’s Manual
2
Table of Contents
Preface
8
Welcome
8
Table of Contents
9
How to Use this Manual
8
1 Introduction
16
Intended Use
16
Principles of Operation
16
Contents
17
Analyzer Components
18
Battery Pack
21
Power Button
22
Consumables
23
Important Safety Instructions
25
2 Setup
26
Important Safety Instructions
26
Choosing a Location
26
Setting up the OPTI CCA-TS2 Analyzer
27
3 Customization
37
Setting Time and Date
37
Setup
38
QC Setup
39
Setting up the Quality Control Material
39
Selecting QC Lockout
41
Customizing Patient Information
44
Setting up Patient Information
44
Suppressing Results for Measured Parameters
47
Setting up Calculated Parameters
48
Setting up Limits for Measurement Parameters
49
Setting up Limits for Calculated Parameters
51
Setting up Test Panels
53
Setting up Correlation Factors
55
Setting up Security
56
Selecting Security Settings
56
Security Settings
57
Setting up User Ids
58
Setting up User Groups
60
Setting up a Password
62
System Reinitialization
63
Miscellaneous System Settings
64
Setting the Printer
64
Defining Units
65
Selecting a Language
67
Hardware Settings
68
Entering the Barometric Pressure
68
Beep Adjustment
69
Standby
70
Setting up Communications
71
Configuring Ethernet Settings
74
Maintenance Setup
76
4 Calibration and Quality Control
78
Calibration
78
QC Overview
79
Proficiency Testing
79
Calibration Verification
80
QC Recommendations
80
Running an SRC Measurement
81
Running a QC Sample
85
Running Controls (OPTI CHECK, OPTI CHECK PLUS)
85
5 Sample Handling and Patient Testing
91
Specimen Collection and Handling
91
Safety
91
Sample Requirements
91
Anticoagulants and Sample Collection Devices
91
Syringes
92
Capillary Tubes
92
OPTI Medical Comfortsamplers
92
Handling and Storage of Samples
93
Test Conditions
94
Sample Preparation
94
Whole Blood Samples
94
Running a Patient Sample
95
Data Management
102
6 Data Management
103
Printing Measurement and Statistics Reports
103
Patient Measurement Reports
103
SRC Measurement Reports
105
SRC Statistics Reports
106
Control Measurement Reports
107
Control Statistics Reports
108
Printing Diagnostics Reports
109
Patient Diagnostics Reports
109
SRC Diagnostics Reports
110
Controls Diagnostics Reports
111
Error Report
112
Miscellaneous Reports
113
Maintenance Report
113
Importing/Exporting Data
114
Exporting Measurement Data
114
Exporting Configuration Data
116
Exporting the Database
117
7 Maintenance
119
Daily Maintenance
119
Weekly Maintenance
119
Quarterly Maintenance - Performing Thb Calibration
120
Annual Maintenance
124
Replacing Peri Pump Cartridge
124
Replacing Gas I/O Port
126
As Needed Maintenance
127
Changing the Gas Bottle
127
Changing the Printer Paper
129
Performing Routine Cleaning
129
8 Diagnostics and Troubleshooting
131
System Error and Warning Messages
131
System Warning Messages
132
System Error Messages
136
System Stop Messages
142
Not Ready Messages
143
Fatal Error Messages
146
Diagnostics
148
Checking Versions
148
Checking System Temperatures
149
Checking Gas Pressure
149
Checking the Leds
150
Verifying Barometric Pressure
150
Checking the Battery Voltage
151
Checking the Cooling Fan
151
Checking the Gas Valve
152
Checking the Valve Drive
152
Checking the Factory Settings (Fset)
153
Checking the Bar Code Scanner
153
Checking the Printer
154
Checking the Optics
155
Checking the Ethernet Interface
156
Checking the Pump Flow
157
Checking the Pump Motor
158
Checking the Display
158
Checking the Touch Screen
159
Gas Test
160
Setting up the B-Lac Cassette
161
Cassette Detect
163
Troubleshooting
164
Troubleshooting Procedure for Thb/So
164
Troubleshooting Procedure for Bar Code Scanner
165
Operating Principles
166
9 Operating Principles
167
Intended Use
167
Principles of Procedure
167
Operation
168
Specimen Collection and Handling
169
Safety
169
Sample Requirements
169
Anticoagulants and Sample Collection Devices
169
Syringes
169
Capillary Tubes
169
OPTI Medical Comfortsamplers
170
Handling and Storage of Samples
170
Procedure
171
Materials Needed
171
Test Conditions
172
Input Values
172
Calculated Values
175
Calibration
175
Quality Control
176
Reference Intervals
177
Specific Performance Characteristics
177
Limitations
178
Interferences
179
Accessories
180
10 Supplies
183
Analyzer
183
Cassettes
183
Controls/Calibrators
183
Consumable Items
184
Accessories
184
Manuals
184
Spare Parts
185
Technical Assistance
185
Warranty Registration (U.S. Market Only)
186
Analytes
187
Ph (Dry Sensor - B-Lac Cassette)
193
Pco
199
PCO (Dry Sensor - B-Lac Cassette)
204
PO (Dry Sensor - B-Lac Cassette)
215
PO 2 (Dry Sensor - B-Lac Cassette)
215
Sodium (Na
221
Potassium (K
227
Ionized Calcium (Ca
233
Chloride (Cl
239
Glucose (Glu)
245
Bun/Urea
252
Bun/Urea
253
Lactate (B-Lac Cassette)
257
Lactate (B-Lac Cassette)
258
Total Hemoglobin Concentration (Cthb) and Hemoglobin Oxygen Saturation (so %)
263
Total Hemoglobin Concentration (Cthb) and Hemoglobin Oxygen Saturation
263
Thb/So2-1
264
Appendix A - Technical Specifications
272
Measurement Range
272
Barometric Pressure
272
Operating Altitude
272
Pollution Degree
272
Operating Parameters
274
Input Values
274
Temperature Corrected Values
276
Reference Ranges
277
Data Management
278
Mains Supply for External Power Supply
278
DC Supply for Instrument
278
Overvoltage Category
278
Dimensions and Weight
278
Classifications
279
Calculated Parameters
279
Temperature
279
Units Used in Measured and Input Parameters for Calculations
279
Conversion Table for Units
280
Equations
280
Appendix B - Menu Structure
286
Basic Patient Report
288
Appendix C - Maintenance Log
288
Appendix D - Report Formats
288
SRC Measurement Report
289
SRC Statistics Report
290
Controls Measurement Report
291
Controls Statistics Report
292
Maintenance Report
293
Error Report
294
B-Lac Setup Report
295
Index
296
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the OPTi CCA-TS2 and is the answer not in the manual?
Ask a question
OPTi CCA-TS2 Specifications
General
Interface
USB
Weight
1.2 kg
Type
Cable and Antenna Analyzer
Impedance
50 Ω
VSWR
1.0 to 65.0
Power Supply
AC Adapter: 100-240 V, 50/60 Hz; Battery: Rechargeable Li-ion