MDI-4000 Series Serial Interface Manual
3.5.8 Reading Operation
Use these settings to enable or disable the reading operation.
When reading is disabled, auto trigger and the TRIGn signal operation are invalid. Also, menu
labels cannot be read. That is, only commands through serial communication are supported.
Enable/Disable Reading Operation
Enable module reading operation
Disable module reading operation
3.5.9 Buzzer and Indicator
These commands apply to “Buzzer” on page 97 and “Good Read LED” on page 99.
Send the confirm buzzer signal from BUZZERn.
Send the error buzzer signal from BUZZERn.
3.5.10 Direct Numerical Input
Use these commands if a command requires additional numerical input. Include these
commands in a single packet with the command that requires the numerical input.
Direct Input Numerical Values
Input in a specified
format
3.6 How to Configure the Scan Engine with a 1D Menu Barcode
You can configure the scan engine to optimize its performance for your particular application by
scanning a series of 1D Menu barcodes specially designed to configure the required functions.
Note: 1D Menu barcodes encode an ID consisting of two to three alphanumeric characters. 1D
Menu barcodes are Code 39 labels with modified start/stop characters and therefore the scan
engine will not acknowledge a 1D menu barcode as a normal barcode.
Configure the Scan Engine with a 1D Menu Barcode
1. Scan the SET menu barcode, ZZ. The scan engine enters menu mode.
2. Scan the options you want to configure.
3. Scan the END menu barcode, ZZ. All settings are saved in non-volatile memory.