MDI-4000 Series Serial Interface Manual
19
You can use Opticon’s “UniversalConfig” to create the 2D menu barcode. For help, contact your
Opticon Sales Representative.
Figure 11: Creating a 2D Menu Barcode with Opticon’s “UniversalConfig.”
3.8 Forced Initialization
If the scan engine is unresponsive, you can force the scan engine to initialize.
Note: When initialization is forced, data read by the scan engine is not sent to the host device.
Force the Scan Engine to Initialize
1. Turn off the scan engine.
2. While keeping TRIGn Low, turn on the power.
3. With TRIGn low, wait for at least 10 seconds. TRIGn becomes active and the scan
engine can read barcodes.
4 Interface
The scan engine supports these serial interfaces:
UART
USB-COM
USB-HID
4.1 UART
UART is one of the most commonly used serial interface protocols. When using the UART
interface, make sure the 12-pin FFC cable is connected to UART signals.
Caution: UART is a standard factory default setting. If the host is using a USB connection
circuit, communication will fail.