MDI-4000 Series Serial Interface Manual
50
Figure 32: Start from TRIGn Signal End
Figure 33: Start from TRIGn Signal Start
5.6.3 Command Trigger Control
To read a command, start reading by sending the “Z” command and stop reading by sending
the “Y” command.
Figure 34: Command Trigger Control
The scan engine stops reading a barcode when the read time elapses. You can also stop the
scan engine from reading a barcode by sending the “Y” command.
Figure 35: Command Trigger Control with Effective Read Time
TRIGn
TRIGn signal duration
Scan time
Read time option
TRIGn
TRIGn signal duration
Scan time
Read time option
“Z” Command
Y Command
Scan time
RxD
or
USB+
“Z” Command
Scan time
Read time option
RxD
or
USB+