MDI-4000 Series Serial Interface Manual
40
5.2.5 Current Consumption of the MDI-4x50
UART
[ V
CC
= 3.3V] (IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol
Conditions
Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
300
450
mA
Standby
Current
Standby
0 ms
I
STB
-
-
26
mA
Low Power
Current
Low
Power
41 ms
I
LOW
Configured
-
1
mA
[ V
CC
= 5.0V] (IF:UART, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol
Conditions
Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
210
320
mA
Standby
Current
Standby
0 ms
I
STB
-
-
20
mA
Low Power
Current
Low
Power
41 ms
I
LOW
Configured
-
0.9
mA
*1
Recovery time is time until ready to scan.
USB
[ V
CC
= 3.3V] (IF:USB, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol
Conditions
Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
300
450
mA
Standby
Current
*2
Standby
0 ms
I
STB
-
-
28
mA
Low Power
Current
*2
Low
Power
43 ms
I
LOW
Configured
*2
-
1.5
mA
[ V
CC
= 5.0V] (IF:USB, T
A
= 25°C)
Item
State
Recovery
Time
*1
Symbol
Conditions
Min.
Typ.
Max.
Unit
Operating
Current
Read
-
I
OP
-
-
210
320
mA
Low Power
Current
Standby
0 ms
I
STB
-
-
20
mA
Low Power
Current
*2
Low
Power
43 ms
I
LOW
Configured
*2
-
1.2
mA
*1
Recovery time is time until ready to scan.
*2
Current value when USB is in “Selective Suspend” mode. When using the USB as virtual COM (USB-COM), use
this USB driver: Opticon USB Code Reader driver version 3.x.x.x.

Table of Contents