MDI-4000 Series Serial Interface Manual
27
4.1.8 Troubleshooting UART
Use this table to find possible solutions to common UART problems.
UART Troubleshooting
Problem
Possible Solutions
Cannot communicate
Make sure communication settings, such as transfer speed and
character format, are correct.
Send the Z2 command. Most communication settings do not take effect
until the Z2 command is sent.
Verify the handshake setting.
No response when
sending command
Make sure communication settings, such as transfer speed and
character format, are correct.
Make sure that the code to be read matches to the character code of
the communication tool.
Nonsensical
characters
Make sure the communication settings are correct.
Check the line-break setting of the communication tool.
4.2 USB-COM
When using the USB-COM interface, make sure the 12-pin FFC cable is connected to the USB
signals. For more information, see USB-COM Interface Signal” on page 28.
Caution: UART is a standard factory default setting. If the host is using a UART
connection circuit, communication will fail.
4.2.1 How to Switch to USB-COM
When you change the interface to USB-COM, the configuration change persists through a
firmware update.
Use one of these methods to change the serial interface to USB-COM:
Send this command:
[X.Z[C01[X.ZZ2
Read this 2D menu barcode: