6 Operation
This chapter explains how to operate the motor and speed controller.
Installing the speed controller
Connecting the AC power
supply and capacitor
Connecting the control
DC power supply and I/O signals
Connecting the motor
Installing the motor
6.1 Power ON
Turn on the power after completing the connection.
When turning on the AC power supply, the POWER LED is lit.
When turning on the DC power supply,
0
is displayed.
When inputting the
DC power supply
When inputting the
AC power supply
Note
When the power is turned on, if the FWD input or REV input is being
ON, the alarm code "
AL46
" (prevention of operation at power-on) is
displayed and the operation cannot be executed.
Before supplying the power, turn both the FWD and REV inputs OFF.
Refer to p.32 for "prevention of operation at power-on."
Test operation
The connection between the motor and speed controller can be checked.
When performing test operation, do not install a load to the motor.
The rotation speed in test operation is 300 r/min.
Power ON
Press the four times.
Test mode
Press the two times.
Test operation
execution screen
Motor rotates
Hold down or
Display on the
operation panel
Rotation speed:
0 r/min (Initial value)
: Forward direction
Operation
: Reverse direction
Before moving to the execution screen, if the FWD
input or REV input is being ON, "
Err
" will be
displayed.
The rotation direction of the gearhead output shaft
varies depending on the gear ratio of the gearhead.
Refer to p.21 for details.
Note
Test operation cannot be executed if the FREE input is being ON. Be sure to execute after turning