Function
−28−
7.3 Items which can be monitored
Operation mode: Monitor mode
Item Display Description
Rotation speed
0
•
The motor shaft rotation speed is displayed.
•
When the "speed reduction ratio" parameter is set, the rotation speed of the gear
output shaft or the conveyor transfer speed is displayed.
•
When the "speed increasing ratio" parameter is set, the rotation speed being
increased by the external mechanism is displayed.
Operation data No.
opE0
The operation data number presently selected is displayed.
Alarm
AL00
When an alarm generates, the corresponding alarm code is displayed. You can also
check and clear alarm records in addition to resetting alarms.
Refer to p.32 for alarm types, alarm codes and alarm reset.
• Alarm record • Alarm reset∗
∗ Only available when an
alarm generates.
Alarm code
1 to 9: Up to the nine most
recent alarm records
Warning
_wn00
When a warning generates, the corresponding warning code is displayed. You can
also check and clear warning records.
Refer to p.34 for warning types and warning codes.
Warning code
1 to 9: Up to the nine most recent alarm records
I/O monitor
io
The ON/OFF status of each I/O signal for the speed controller can be checked. If the
signal is ON, the corresponding digit is lit. If the signal is OFF, the digit is unlit.
Also, the setting voltage of the external speed setter can be checked.
IN0
IN1
IN3
IN4
IN5
IN2
OUT0
OUT1
• Input signal
• Output signal∗
∗ The alarm output is being ON while the
product operates normally.
7.4 Setting the operation data
Up to 4 operation data can be set using the operation panel, and the motor can be
operated by selecting the data based on a combination of ON/OFF status of the M0
and M1 inputs.
Refer to p.23 for the setting procedure and operating method.
Acceleration time Deceleration time
Rotation
speed
[s]
Operation mode: Data mode
Item Display
*
2
Description Setting range Initial value
Rotation speed
*
1
rEu
Sets the rotation speed.
Set as the rotation speed of the motor output shaft.
50 Hz: 0, 90 to 1400 r/min
60 Hz: 0, 90 to 1600 r/min
0
Acceleration time
tA
Sets the acceleration time and deceleration time.
Refer to p.21 for details.
0.0 to 15.0 s 0.0
Deceleration time
td
Initialization
in i
Restores the operation data to the initial value. – –
*1
If the product is operated at 50 Hz when the rotation speed exceeding 1400 r/min has been set, the motor will rotate around 1420 r/min
although it is out of the setting range.
*2
The digit (0 to 3), which represents the operation data number, will be displayed at the end of the string.
Operation data No.0:
rEu0
Note
Do not turn the control DC power supply while the display is blinking after executing the data setting or
initialization. Doing so may damage the data.