10. Turn the Main Power Switch on the back and the Power Switch on the left side of the machine to the
ON position.
11. Use this Master Firmware Card to update the firmware on other machines.
3.6.6. Erasing the Master Firmware Card
1. Turn the Power Switch on the left side and the Main Power Switch on the back of the machine to the
OFF position. (See 3.6.7.)
2. Install the Master Firmware Card into the machine.
3. Turn the Main Power Switch on the back and the Power Switch on the left side of the machine to the
ON position.
4. Press the "FUNCTION", "ORIGINAL SIZE (LEDGER/A3)" and "3" keys simultaneously in that order
to enter the Service Mode.
5. Perform the Service Mode F9-09 (Update Program Card).
6. After the Flash Memory Card is erased, machine prompts "Update Program Card?". Press "NO".
7. Press "STOP" first and then press "FUNCTION" + "CLEAR" keys simultaneously to return to
standby.
8. Turn the Power Switch on the left side and the Main Power Switch on the back of the machine to the
OFF position. (See 3.6.7.)
9. Remove the blank Flash Memory Card from the machine.
10. Repeat from Step 2 above if you are erasing another Master Firmware Card.
3.6.7. Notice after installing the HDD option
After the Hard Disc Drive Unit is installed, to prevent a Disc Scan Function from being performed (similar
to when the power is abruptly interrupted to the PC), it is important to follow the step sequence below
when turing OFF the Power Switches on the machine.
1. Turn the Power Switch on the left side of the machine to the OFF position first.
2. Wait approximately 10 seconds while the machine writes the closing status onto the Hard Disc Drive
Unit.
3. Turn the Main Power Switch on the back of the machine to the OFF position.