E3- 03 Toner Density Sensor gain 1. Sensor connector is disconnected.
2. Sensor is defective.
3. SPC PCB connector is disconnected.
4. SPC PCB is defective.
E3- 10 High Voltage Power Supply
leak (1) - Grid Charge Voltage
1. HVPS connector is disconnected.
2. HVPS is defective.
3. SPC PCB connector is disconnected.
4. SPC PCB is defective.
5. Corona Wire is abnormal. (Check for: contamination
with foreign particles, broken, not installed in the
proper position or the tension is loose)
E3- 11 High Voltage Power Supply
leak (2) - Separation Voltage
E3- 12 High Voltage Power Supply
leak (3) - Transfer Current
E3- 13 High Voltage Power Supply
leak (4) - Developer AC Bias
1. HVPS connector is disconnected.
2. HVPS is defective.
3. SPC PCB connector is disconnected.
4. SPC PCB is defective.
5. Developer Unit Bias Terminal is contaminated with
Toner.
E3- 20 Main Motor rotation 1. Drive Mechanism is defective.
2. Main Motor connector is disconnected.
3. Main Motor is defective.
4. DRV PCB connector is disconnected.
5. DRV PCB is defective.
6. SPC PCB connector is disconnected.
7. SPC PCB is defective.
8. LVPS is defective.
E3- 21 Dust Collection Fan Motor
rotation
1. Dust Collection Fan connector is disconnected.
2. Dust Collection Fan is defective.
3. DRV PCB connector is disconnected.
4. DRV PCB is defective.
5. SPC PCB connector is disconnected.
6. SPC PCB is defective.
7. LVPS is defective.
E3- 23 Suction Fan rotation 1. Suction Fan connector is disconnected.
2. Suction Fan is defective.
3. DRV PCB connector is disconnected.
4. DRV PCB is defective.
5. SPC PCB connector is disconnected.
6. SPC PCB is defective.
7. LVPS is defective.
E3- 24 Ozone Fan 2 rotation 1. Ozone Fan 2 connector is disconnected.
2. Ozone Fan 2 is defective.
3. DRV PCB connector is disconnected.
4. DRV PCB is defective.
5. SPC PCB connector is disconnected.
6. SPC PCB is defective.
7. LVPS is defective.
E3: Development System Error
Code Function Check Points