184
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
E2: Lift DC Motor Error
Code Function Check Points
E2- 01
E2- 02
Lift Motor rotation
(1st Paper Tray)
Lift Motor rotation
(2nd Paper Tray)
1. Level Sensor connector is disconnected.
2. Level Sensor is defective.
3. Lift Mechanism is defective.
4. Lift Motor connector is disconnected.
5. Lift Motor is defective.
6. LVPS connector is disconnected.
7. LVPS is defective.
8. SPC PCB connector is disconnected.
9. SPC PCB is defective.
10. APF PCB connector is disconnected.
11. APF PCB is defective.
12. Paper Feed Module connector is disconnected.
E2- 03
E2- 04
Lift Motor rotation
(3rd Paper Tray)
Lift Motor rotation
(4th Paper Tray)
E2- 06
E2- 07
LCT ascending operation (UP)
LCT descending operation
(DOWN)
1. LCT connector is disconnected.
2. Upper Limit Sensor connector is disconnected.
3. Upper Limit Sensor is defective.
4. Lift Mechanism is defective.
5. Lift Motor connector is disconnected.
6. Lift Motor is defective.
7. Lower Limit Sensor connector is disconnected.
8. Lower Limit Sensor is defective.
9. LCT PCB connector is disconnected.
10. LCT PCB is defective.
11. LVPS connector is disconnected.
12. LVPS is defective.
13. SPC PCB connector is disconnected.
14. SPC PCB is defective.
E2- 10 System Console Drive Motor
rotation
1. System Console Cable is disconnected.
2. Drive Mechanism is defective.
3. Drive Motor connector is disconnected.
4. Drive Motor is defective.
5. APF PCB connector is disconnected.
6. APF PCB is defective.
7. LVPS connector is disconnected.
8. LVPS is defective.
9. SPC PCB connector is disconnected.
10. SPC PCB is defective.
E3: Development System Error
Code Function Check Points
E3- 01 Toner Bottle Motor rotation 1. Toner Bottle Home Position Sensor connector is
disconnected.
2. Toner Bottle Home Position Sensor is defective.
3. Toner Bottle Motor connector is disconnected.
4. Toner Bottle Motor is defective.
5. Toner Bottle Motor Drive Mechanism is defective.
6. Toner Bottle is installed incorrectly.
7. SPC PCB connector is disconnected.
8. SPC PCB is defective.