193
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
418 RCV C Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
Line quality is poor. (There are
excessive errors in received data)
FXB PCB or MJR PCB is defective.
420 RCV B T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
There is wrong incoming call.
(Non-facsimile communication)
Transmitter is defective.
FXB PCB or MJR PCB is defective.
421 RCV B Busy Tone is detected after
sending NSF Signal.
Remote station disconnected the line.
Wrong number is dialed.
422 XMT B Content of NSF (or DIS) or NSC
(or DTC) was invalid.
There is an incompatibility.
427 G3
RCV
B DCN received to NSF/CSI/DIS
transmitted.
The interface is incompatible.
433 XMT
RCV
B, D T.30 Protocol abnormal. Defective remote station.
434 XMT or RCV B CD (response from Modem) did
not turn OFF within 180 sec. after
receiver detected FLAG signal.
Remote unit is defective.
FXB PCB or MJR PCB is defective.
436 G3 RX C DCN received after transmitting
FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456 RCV B Received relay transfer request or
confidential document to distribute
to an end receiving station or all
confidential mailboxes are used.
457 RELAY XMT
CONF. XMT/
POLL
B Remote unit does not have
Relayed XMT or Confidential
Comm. capability.
459 RCV C Failed training in Phase C. Line quality is poor. (Training signal is
distorted due to line noise)
FXB PCB or MJR PCB is defective.
490 RCV C Sum of error lines exceeded the
limit (Function Parameter No. 70)
of 64 lines.
Line quality is poor.
FXB PCB or MJR PCB is defective.
494 RCV C Interval between two EOLs was
more than 10 sec. when receiver
received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
FXB PCB or MJR PCB is defective.
495 XMT
RCV
C During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
FXB PCB or MJR PCB is defective.
496 XMT C CS of modem is not able to turn
ON.
FXB PCB is defective.
501 XMT/
RCV(V.34)
B Incompatible Modem on the
Remote unit.
502 XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
FXB PCB or MJR PCB is defective.