228
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
14 Side adjust (Tray 4) Adjustment of LSU side-side (4th Tray). -8 - +7
0.5mm
15 Side adjust (LCT) Adjustment of LSU side-side (LCT). -8 - +7
0.5mm
16 Side adjust (ADU) Adjustment of LSU side-side (ADU). -8 - +7
0.5mm
17 Grid standard voltage Adjustment of Grid standard voltage. -92 - +61
3.27V
18 Laser standard power Laser power compensation adjustment. -56 - +25
19 Bias standard vol.DC Adjustment of bias standard voltage. -77 - 76
3.92V
20 Print Contrast Adjust Halftone adjustment, Print density
for Photo Mode.
(-) : Darker.
(+) : Lighter.
-7 - +7
21 TDC gain voltage Adjustment of toner density sensor gain
voltage.
-86 - +40
0.033V
22 (Factory use only) QUANTUM parameter 1
23 (Factory use only) QUANTUM parameter 2
24 Bias standard vol. AC
(Factory use only)
AC Bias standard voltage adjustment -10 - +10
20V
25 Bias Duty Ratio
(Factory use only)
Bias duty ratio adjustment -5 - +5 1%
26 TDC judgment level Adjustment of toner supply starting judgement
voltage level.
-26 - +26
19.5mV
27 Bias Frequency
(Factory use only)
AC Bias frequency adjustment -2 - +2
1KHz
28 Quantum white density Adjustment of standard white density level.
(Should not be adjusted in the field, and must
be set to "0")
-99 - +99
29 Quantum black density Adjustment of standard black density level.
(Should not be adjusted in the field, and must
be set to "0")
-99 - +99
30 Laser power adj. 2 level Laser power compensation adjustment in 2
value mode.
-56 - +25
31 Fuser temperature Adjustment of fuser temperature. -15 - +15
0.833°C
32 Fuser temperature. edge Temperature compensation for edges -15 - +15
0.833°C
33 TDC max. read only Set by Digital QUANTUM (QUARC) control Read only
34 TDC min. read only Set by Digital QUANTUM (QUARC) control Read only
35 TDC ave. read only Set by Digital QUANTUM (QUARC) control Read only
36 Paper Loop (Tray1, cop) Individual Fine Adjustment for Tray 1 -99 - +99
37 Toner Save Mode level adjust Adjustment of threshold level. -255 - +255
38 ID standard voltage Adjustment of judgement standard voltage. -35 - +35
39 LSU unit PWM adjust 2 Adjustment of PWM value of LSU. -99 - +99
40 T corona current 1sided Adjustment of transfer corona current. -10 - +10
5.22uA
F6 Mode
No. Item Remarks
Setting