Class Function Details
Initial value
Memory
chan
g
e*
Ref.
p
a
g
e
Output Settings
Judgment Output
Selection
Sets the operation of the output block.
Default: 2-state
{
3-23
Displace
ment
Judgment
Threshold a
Sets threshold a
and threshold b.
Default: +(detection range)
Default: -(detection range)
{
3-25
Threshold b
H
y
steresis
Sets the hysteresis.
Default: +(0.2% of setting range)
{
Judgment Output OFF
Dela
y
Delays the timing of judgment output switched OFF
from ON.
Default: OFF
{
3-27
Measurement Value
Dis
p
la
y
on Panel
Turns OFF the rightmost digits on the digital display.
Default: SET 1
{
3-29
Analog Settings
Analog Output
Selection
Selects the desired output type from current output and
voltage output.
Default: Current output
{
3-30
Analog
Scaling
Meas A
Performs scaling
the analog current
output and the
analog voltage
output to any
desired value.
Default: Negative measurement range
{
3-31
Meas B
Default: Positive measurement range
{
Current a
Default: +4.000 mA
{
Current b
Default: +20.000 mA
{
Voltage a
Default: 0.000 V
{
Voltage b
Default: 10.000 V
{
Alarm Settings
Analog Output at Alarm
Sets the analog output status at alarm operation.
Default: Holds previous value
{
3-33
Digital Output at Alarm
Sets the digital output status at alarm operation.
Default: Holds previous value
{
3-34
Alarm Delay Times
Holds the previous normal value up to the setting
number of times if an alarm is issued.
Default: 8 times
{
3-35
COM Settings
Terminating Resistor
Selection
Selects the terminating resistor for the sensor head
connecting to the host device over RS-422/485.
Default: R3
3-36
Sensor no.
Sets the number of each sensor head multi connected
to an RS-485 device.
Default: 01
3-37
Baud rate
Sets the communication speed.
Default: 38400 bps
3-38
Connection Mode
Selects the performance settings for measurement data
output to the host device.
Default: RS-485 Multiple
3-39
Sending Delay Time
Set the sensor's delay time in response to each
command transmitted from the host device.
Default: 0ms
3-40
System Settings
Timin
g
Mode
Sets the timing input mode.
Default: Hold
3-41
Laser Control
Switches laser emission/stop.
Default: Emission
3-42
Eco Mode
Turns OFF the LED indicators on the control panel for
energy saving while the system is in RUN mode.
Default: Eco OFF
3-43
View Version
Displays the program version of the sensor. - 3-44
Initialization
Initializes the memory settings currently in use.
¯
3-45
Save
Saves all memory settings.
¯
3-46
Timin
g
Holds the measurement value.
Default: OFF
-3-47
Ramco Innovations
(
800
)
280-6933 www.panasonicsensors.com nsales
@
ramcoi.com