Chapter 6Maintenance — Light source/temperature indicators
ENGLISH - 261
Temperature indicator <TEMP>
Indicator status Status Solution
Lighting red
f Warm-up status
f Wait ve minutes when the power is turned on while the temperature is low
(approximately 0 °C (32 °F)).
f Use the projector in an appropriate operating environment temperature
*1
.
f Internal temperature is high
(warning).
f Remove any objects if they are blocking the intake/exhaust vents.
f Use the projector in an appropriate operating environment temperature
*1
.
f Do not install the projector at an altitude of 4 200 m (13 780') or higher
above sea level. (Altitude of 4 200 m (13 780') above sea level is the
maximum height that the performance of this projector is guaranteed.)
Blinking red
(2 times)
f Internal temperature is high (standby
status).
Blinking red
(3 times)
f The cooling fan has stopped.
f Turn the <MAIN POWER> switch to <OFF> (x page 76), and consult
your dealer.
*1 For the operating environment temperature of the projector, refer to “Operating environment” (x page 284).
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.