17/200
2. BASIC CONTROL COMMAND
2.1. POWER ON (LIGHT ON) [PON]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 4Eh 03h
Character A D Z Z ; P O N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
○ ○ ○ ○ ○ ○ ○ △ ○ ×
Note:
・When you check whether to have succeeded in power-on, confirm it by QPW (Query Power) command after receiving
the callback of PON command.
・REMOTE2 is given to priority. In the case of a different command from a setup of REMOTE2, ER401 is returned.
2.2. POWER OFF (Standby) [POF]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 50h 4Fh 46h 03h
Character A D Z Z ; P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
○ ○ ○ ○ ○ ○ ○ △ ○ ×
Note:
・When you check whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving
the callback of PON command.
・REMOTE2 is given to priority. In the case of a different command from a setup of REMOTE2, ER401 is returned.
2.3. FREEZE [OFZ]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 46h 5Ah 3Ah *1 03h
Character A D Z Z ; O F Z : *2
Parameters(*1,*2)
Freeze OFF Freeze ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h
Character O F Z : *2
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × × × ○ ○ ○ ○ ×
2.4. AUTO SETUP [OAS]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 53h 03h
Character A D Z Z ; O A S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × × ○ ○ × ○ ○ ×
Note:
・The signal of non-compliant, returns the ER401.