EasyManua.ls Logo

Panasonic PT-RZ670 series

Panasonic PT-RZ670 series
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38/200
2.71. ZOOM - INTERLOCKED [OZS]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 5Ah 53h 3Ah
Character A D Z Z ; O Z S :
Hexadecimal *1 03h
Character *2
Parameters(*1,*2)
OFF ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 5Ah 53h 3Ah *1 03h
Character O Z S : *2
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × × × × ×
2.72. ZOOM - MODE [OZT]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 5Ah 54h 3Ah
Character A D Z Z ; O Z T :
Hexadecimal *1 03h
Character *2
Parameters(*1,*2)
INTERNAL FULL
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 5Ah 54h 3Ah *1 03h
Character O Z T : *2
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × × × × ×
Note:
・When [ASPECT] is not set to [DEFAULT], ER401 returned.
2.73. CLOCK PHASE [VCP]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 50h 3Ah
Character A D Z Z ; V C P :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters(*1,*2,*3,*4,*5,*6)
0 1 2
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2
29 30 31
Hexadecimal 30h 32h 39h 30h 33h 30h 30h 33h 31h
Character 0 2 9 0 3 0 0 3 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 43h 50h 3Ah *1 *3 *5 03h
Character V C P : *2 *4 *6
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × × × × ×
Note:
・Acceptability is possible only if it is selected or RGB2 or RGB1. Otherwise, it returns the ER401.