2.472. QUERY SDI IN - 3GSDI MAPPING [QVX:SGMI1]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 47h 4Dh 49h 31h 03h
Character S G M I 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 47h 4Dh 49h 31h 3Dh 2Bh *1 *3
Character S G M I 1 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× ×
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
AUTO LEVEL
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
LEVEL B
Hexadecimal 30h 30h 30h 30h 32h
Character 0 0 0 0 2
Note:
・Other than RZ670, ER401 is returned.
2.473. QUERY BRIGHTNESS CONTROL - SETUP - CALIBRATION TIME [QVX:BTMI1]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 42h 54h 4Dh 49h 31h 03h
Character B T M I 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 42h 54h 4Dh 49h 31h 3Dh 2Bh *1 *3
Character B T M I 1 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
×
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
OFF 00:01
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
23:59 00:00
Hexadecimal 30h 32h 33h 35h 39h 30h 32h 34h 30h 30h
Character 0 2 3 5 9 0 2 4 0 0
2.474. QUERY BRIGHTNESS CONTROL - SETUP - CALIBRATION MESSAGE [QVX:BMGI1]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 42h 4Dh 47h 49h 31h 03h
Character B M G I 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 42h 4Dh 47h 49h 31h 3Dh 2Bh *1 *3
Character B M G I 1 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
×
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
OFF ON
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1