2.478. QUERY BACKUP INPUT SETTING – BACKUP INPUT MODE [QVX:BACI2]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 88h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 42h 41h 43h 49h 32h 03h
Character B A C I 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 42h 41h 43h 49h 32h 3Dh 2Bh
Character B A C I 2 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
○ ○ × ○ ○ ○ ○ ○ × ○
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
OFF ON
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
2.479. QUERY BACKUP INPUT SETTING – AUTOMATIC SWITCHING [QVX:BACI3]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 88h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 42h 41h 43h 49h 33h 03h
Character B A C I 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 42h 41h 43h 49h 33h 3Dh 2Bh
Character B A C I 3 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
○ ○ × ○ ○ ○ ○ ○ × ○
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
DISABLE ENABLE
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
2.480. QUERY BACKUP INPUT SETTING – BACKUP INPUT STATUS [QVX:BACI4]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 88h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 42h 41h 43h 49h 34h 03h
Character B A C I 4
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 42h 41h 43h 49h 34h 3Dh 2Bh
Character B A C I 4 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Character *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
○ × × ○ ○ × × ○ × ○
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
INACTIVE ACTIVE
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1