2.444. QUERY SCHEDULE - COMMAND SETTING [QVX:SCCS]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 43h 43h 53h *1 3Dh *3 *5 03h
Character S C C S *2 = *4 *6
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 43h 43h 53h *1 3Dh 2Bh *3 *5
Character S C C S *2 = + *4 *6
Hexadecimal *7 *9 *11 *13 *15 *17 03h
Character *8 *10 *12 *14 *16 *18
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
×
Parameters(*1,*2)
PROGRAM 1 PROGRAM 2 PROGRAM 3 PROGRAM 4
Hexadecimal 31h 32h 33h 34h
Character 1 2 3 4
PROGRAM 5 PROGRAM 6 PROGRAM 7
Hexadecimal 35h 36h 37h
Character 5 6 7
Parameters(*3, *4, *5, *6)
COMMAND 1 COMMAND 2 COMMAND 3 COMMAND 4
Hexadecimal 30h 31h 30h 32h 30h 33h 30h 34h
Character 0 1 0 2 0 3 0 4
COMMAND 13 COMMAND 14 COMMAND 15 COMMAND 16
Hexadecimal 31h 33h 31h 34h 31h 35h 31h 36h
Character 1 3 1 4 1 5 1 6
Parameters(*7, *8, *9, *10)
COMMAND Del STANDBY POWER ON SHUTTER OPEN SHUTTER CLOSE
Hexadecimal 30h 30h 31h 30h 31h 31h 32h 30h 32h 31h
Character 0 0 1 0 1 1 2 0 2 1
RGB1 INPUT RGB2 INPUT DVI-D INPUT SDI INPUT HDMI INPUT
Hexadecimal 33h 31h 33h 32h 35h 31h 35h 32h 35h 33h
Character 3 1 3 2 5 1 5 2 5 3
NORMAL ECO LONG LIFE1 LONG LIFE2 LONG LIFE3
Hexadecimal 37h 30h 37h 31h 37h 32h 37h 33h 37h 34h
Character 7 0 7 1 7 2 7 3 7 4
USER1 USER2 USER3 DIGITAL LINK INPUT 1
Hexadecimal 37h 35h 37h 36h 37h 37h 42h 30h 42h 31h
Character 7 5 7 6 7 7 B 0 B 1
INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6
Hexadecimal 42h 42h 42h 33h 42h 34h 42h 35h 42h 36h
Character B 2 B 3 B 4 B 5 B 6
INPUT 7 INPUT 8 INPUT 9 INPUT 10 P IN P OFF
Hexadecimal 42h 37h 42h 38h 42h 39h 42h 41h 39h 30h
Character B 7 B 8 B 9 B A 9 0
P IN P USER1 P IN P USER2 P IN P USER3
Hexadecimal 39h 31h 39h 32h 39h 33h
Character 9 1 9 2 9 3
2.445. QUERY STARTUP INPUT SELECT [QVX:SISS1]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 58h 3Ah
Character A D Z Z ; Q V X :
Hexadecimal 53h 49h 53h 53h 31h 03h
Character S I S S 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 49h 53h 53h 31h 3Dh 2Bh *1 *3
Character S I S S 1 = + *2 *4
Hexadecimal *5 *7 *9 03h
Character *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
×

Table of Contents