Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 58h 58h 3Ah 42h 43h 53h 49h 30h
Character V X X : B C S I 0
Hexadecimal 3Dh 2Bh *1 *3 *5 *7 *9 03h
Character = + *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × ×
2.202. SCHEDULE [VXX:SCHI0]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 58h 58h 3Ah
Character A D Z Z ; V X X :
Hexadecimal 53h 43h 48h 49h 30h 3Dh 2Bh *1 *3 *5
Character S C H I 0 = + *2 *4 *6
Hexadecimal *7 *9 03h
Character *8 *10
Parameters(*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
OFF
ON
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 0 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 58h 58h 3Ah 53h 43h 48h 49h 30h
Character V X X : S C H I 0
Hexadecimal 3Dh 2Bh *1 *3 *5 *7 *9 03h
Character = + *2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × ×
2.203. SCHEDULE - PROGRAM ASSIGN [VXX:SPGI]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 58h 58h 3Ah
Character A D Z Z ; V X X :
Hexadecimal 53h 50h 47h 49h *1 3Dh 2Bh *3 *5 *7
Character S P G I *2 = + *4 *6 *8
Hexadecimal *9 *11 03h
Character *10 *12
Parameters(*1,*2)
Sun Mon Tue Wed Thu Fri Sat
Hexadecimal 30h 31h 32h 33h 34h 35h 36h
Character 0 1 2 3 4 5 6
Parameters(*3, *4, *5, *6, *7, *8, *9, *10, *11, *12)
OFF PROGRAM 1 PROGRAM 2
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 30h 30h 31h 30h 30h 30h 30h 32h
Character 0 0 0 0 0 0 0 0 0 1 0 0 0 0 2
PROGRAM 3 PROGRAM 4 PROGRAM 5
Hexadecimal 30h 30h 30h 30h 33h 30h 30h 30h 30h 34h 30h 30h 30h 30h 35h
Character 0 0 0 0 3 0 0 0 0 4 0 0 0 0 5
PROGRAM 6 PROGRAM 7
Hexadecimal 30h 30h 30h 30h 36h 30h 30h 30h 30h 37h
Character 0 0 0 0 6 0 0 0 0 7
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 58h 58h 3Ah 53h 50h 47h 49h *1
Character V X X : S P G I *2
Hexadecimal 3Dh 2Bh *3 *5 *7 *9 *11 03h
Character = + *4 *6 *8 *10 *12
Acceptability
SECURITY STANDBY ECO
STANDBY
NO
SIGNAL
SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × × ×