2.5. SHUTTER [OSH]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 48h 3Ah *1 03h
Character A D Z Z ; O S H : *2
Parameters(*1,*2)
SHUTTER OFF SHUTTER ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 48h 3Ah *1 03h
Character O S H : *2
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× ×
Note:
・REMOTE2 is given to priority. In the case of a different command from a setup of REMOTE2, ER401 is returned.
2.6. INPUT SELECT [IIS]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 49h 49h 53h 3Ah
Character A D Z Z ; I I S :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters(*1,*2,*3,*4,*5,*6)
RGB1 RGB2 DIGITAL LINK
Hexadecimal 52h 47h 31h 52h 47h 32h 44h 4Ch 31h
Character R G 1 R G 2 D L 1
DVI HDMI SDI
Hexadecimal 44h 56h 49h 48h 44h 31h 53h 44h 31h
Character D V I H D 1 S D 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 49h 49h 53h 3Ah *1 *3 *5 03h
Character I I S : *2 *4 *6
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × ×
Note:
・REMOTE2 is given to priority. Calls back ER402 if the input select of REMOTE2 is available.
・If PT-RZ670 parameters SD1is available. In other case, ER401 is returned.
2.7. INPUT SELECT (DIGITAL LINK) [IIS]
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 49h 49h 53h 3Ah
Character A D Z Z ; I I S :
Hexadecimal 44h 4Ch 31h 3Ah *1 *3 *5 03h
Character D L 1 : *2 *4 *6
Parameters (*1,*2,*3,*4,*5,*6)
HDMI1 HDMI2 COMPUTER1
Hexadecimal 48h 44h 31h 48h 44h 32h 50h 43h 31h
Character H D 1 H D 2 P C 1
COMPUTER2 S-VIDEO VIDEO
Hexadecimal 50h 43h 32h 53h 56h 44h 56h 49h 44h
Character P C 2 S V D V I D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 49h 49h 53h 3Ah 44h 4Ch 31h 3Ah
Character I I S : D L 1 :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Acceptability
SECURITY STANDBY ECO
STANDBY
NO SIGNAL SHUTTER FREEZE TEST
PATTERN
REMOTE2 P IN P LENS
HOME
× × ×
Note:
REMOTE2 is given to priority. Calls back Er402 if the input select of REMOTE2 is available.
・It is effective only when the digital interface box is connected.