200/200
35
Unused Unused
34 Exhaust air temperature sensor disconnected
Exhaust air thermosensor has breaking of wire, or connector (M11/BR4) is
disconnected.
33
Optical module temperature sensor
disconnected
DMD thermosensor has breaking of wire, or connector (DG4/FM2) is disconnected.
32 Intake air temperature sensor disconnected
Intake air thermosensor has breaking of wire, or connector (M11/DG18) is
disconnected.
31 Luminance sensor error
Luminance sensor proportion is abnormal.
Luminance is abnormal.
30 Unused
29 Unused
28 Low AC voltage warning Low AC voltage.
27 PW2 error (FPGA)
Phosphor1 wheel or circuit are failure.
26 PW2 error (FM)
25 PW1 error (FPGA)
Phosphor2 wheel or circuit are failure.
24 PW1 error (FM)
23 AC7
Internal Warning.
22 AC6
21 AC5
20 AC4
19 AC3
18 AC2
17 AC1
16 AC0
15 AA7
14 AA6
13 AA5
12 AA4
11 AA3
10 AA2
9 AA1
8 AA0
7 Optical module low temperature error
The temperature inside this projector has become high or ambient
temperature is too low.
- The ventilation holes may be closed.
- The ambient temperature in the place of use may
be too high or low.
- Heatsink mounting is abnormal
- High altitude mode is mis select
6 Exhaust air high temperature error
5 Optical module high temperature error
4 Intake air temperature error
3 Optical module low temperature warning
2 Exhaust air high temperature warning
1 Optical module high temperature warning
0 Intake air temperature warning