31
Arming and Disarming Options
Arming Follows Partition
(default = disabled) A partition can be set to follow the arming and disarming status of one or more partitions.
Trouble Latch
SECTION [3033]: OPTION [6]
With the Trouble Latch feature disabled, when a trouble occurs and is corrected, the trouble is automatically cleared and no longer displayed. With the Trouble Latch
feature enabled, the trouble will remain displayed until it is manually cleared by the user. To clear the trouble, the user must enter the trouble display and then exit
the trouble display. For LCD keypads, press [
CLEAR] to exit.
Only troubles that have been corrected can be cleared. If a trouble has not been corrected, it will continue to be displayed even if the user tries to clear the trouble
by using the method described above.
Restrict Arming on Supervision Loss
SECTION [3034]: OPTION [4]
(default = disabled) When enabled, arming is restricted if a supervision loss signal from the Magellan Wireless System RTX3 is received.
Restrict Arming on Tamper
SECTION [3034]: OPTION [8]
(default = disabled) When enabled, the control panel prevents arming if it detects a tamper on a zone or module page 37. Partitions will not arm until the Installer
Code is entered and the tamper trouble conditions are corrected.
Restrict Arming on AC Failure
SECTION [3035]: OPTION [1]
(default = disabled) When enabled, the control panel prevent arming if it detects a loss of AC power.
Restrict Arming on Battery Failure
SECTION [3035]: OPTION [2]
(default = disabled) When enabled, the control panel prevents arming if it detects a battery loss or if the battery voltage is less than 10.5V.
Restrict Arming on Bell or Auxiliary Failure
SECTION [3035]: OPTION [3]
(default = disabled) When enabled, the control panel prevents arming if:
the bell or siren is disconnected
the Bell Output has exceeded its current limits
the Auxiliary Outputs have exceeded their current limits
Restrict Arming on TLM Failure
SECTION [3035]: OPTION [4]
(default = disabled) When enabled, the control panel can prevent arming if it is unable to access the telephone line.
Restrict Arming on Module Troubles
SECTION [3035]: OPTION [5]
(default = disabled) When is enabled, the control panel uses the same Restrict Arming options for the modules connected to the Digiplex bus.
Section [3035]: Option [8]
(default = disabled) When is enabled, the control panel restricts arming if on failure to communicate if trouble in group dialer/PCS and/or IP.
Restrict Arming on Anti Mask Troubles
Section [3029]: Option [5]
(default = disabled) When is enabled, the control panel restricts arming if trouble in Anti-Mask.
Section: Partition arms & disarms with:
Partition 1: [3121]
Partition 2: [3221]
Partition 3: [3321]
Partition 4: [3421]
Partition 5: [3521]
Partition 6: [3621]
Partition 7: [3721]
Partition 8: [3821]
Option [1] = Partition 1
Option [2] = Partition 2
Option [3] = Partition 3
Option [4] = Partition 4
Option [5] = Partition 5
Option [6] = Partition 6
Option [7] = Partition 7
Option [8] = Partition 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox EVOHD+ and is the answer not in the manual?

Paradox EVOHD+ Specifications

General IconGeneral
BrandParadox
ModelEVOHD+
CategorySecurity System
LanguageEnglish

Related product manuals