40
EVOHD+ Installation Guide
Reporting Enabled
SECTION [3036]: OPTION [3]
(default = disabled) If enabled, the control panel verifies if a report code was programmed in the section corresponding to event that happened. If a report code is
programmed, the control panel dials the monitoring station telephone number. When the monitoring station answers, the control panel transmits the system
account code and the programmed report code.
IP/ PCS / GPRS Reporting
For more information on setting up IP/GPRS reporting please refer to the PCS Series Reference and Installation manual or the IP150+ Installation manual.
The EVOHD+ has two separate serial outputs allow connecting reporting devices to both ports. Serial 1 is a Master, meaning all reporting will go first to Serial 1. Serial 2 is
secondary, meaning reporting will redirect to Serial 2 only if Serial 1 fails. This allows for the connection of an IP150+ in Serial 1 and a PCS in Serial 2, or any combination of
reporting devices to the two serials.
Report Codes
Report codes are 2-digit or 1-digit hexadecimal value. The Ademco Slow, Silent Knight, Sescoa formats support 1-digit report codes.
The transmission is defined by these
two items: Reporting Formats (see section on page 45) and Event Call Direction (see section on page 46). If you are using the Ademco CID or SIA formats, an Auto
Report Code Programming feature is available (see section on page 48).
Zone Alarm and Alarm Restore Report Codes
SECTION [0400]: FIRST AND SECOND BRACKETS
SECTIONS [0201] TO [0296]: FIRST AND SECOND BRACKETS
The first set of 2 digits in the sections refer to the Alarm Report Codes that identify which zones generated an alarm. The second set of 2 digits refer to the Alarm
Restore Report Codes when a zone closes or once the bell has cut-off (see section on page 36). Refer to Zone Restore Report Options in (see section on page 48).
Tamper and Tamper Restore Report Codes
section [0400]: Third and Fourth Brackets
S
ECTIONS [0201] TO [0296]: THIRD AND FOURTH BRACKETS
The third set of 2 digits refer to the Tamper Report Codes. The fourth set of 2 digits refer to the Tamper Restore Report Codes.
Keyswitch Arming
SECTIONS [0701] TO [0732]
Each section from [0701] to [0732] corresponds to a keyswitch from 1 to 32. The control panel can send the report code to the monitoring station identifying which
keyswitch was used to arm. It will not send report codes for keyswitches that are defined with the PGM Activation definition.
Keyswitch Disarming
SECTIONS [0801] TO [0832]
Each section from [0801] to [0832] corresponds to a keyswitch from 1 to 32. The control panel can send a report code to the monitoring station identifying which
keyswitch was used to disarm. It can transmit the report codes every time a partition is disarmed or only following an alarm. It will not send report codes for
keyswitches that are defined with the PGM Activation definition.
Access Codes Arming
SECTIONS [2001] TO [2099]
A report code can be programmed for each user access code from 01 to 98 in sections [2001] to [2098]. User access codes from 99 to 999 use a common report
code in section [2099]. The control panel can send the report code identifying which access code was used to arm the system.
Access Codes Disarming
SECTIONS [2101] TO [2199]
A report code can be programmed for each user access code from 01 to 98 in sections [2101] to [2198]. User access codes from 99 to 999 use a common report
code programmed in section [2199].The control panel can send the report code to the monitoring station identifying which access code was used to disarm the
system. It can be transmitted when a partition is disarmed or only following an alarm. Also, see page 48.