EVOHD+ Installation Guide
37
Police Code Timer
(default = 000) If an alarm condition occurs on a zone, the control panel generates an alarm and triggers the Police Code Timer. The Police Code programmed in
[3934] will only be sent if one of the following conditions occurs during the delay:
1. An alarm occurs on another zone.
2. The zone in alarm restores and reoccurs.
Key in the desired 3-digit delay value (001 to 255 minutes, 000 = disabled) into the section corresponding to the desired partition:
Refer to Intellizone Options on page 25 to set it up so that a police code is only generated on Zone Crossing.
Tamper Recognition Options
SECTION [3034]: OPTIONS [5] AND [6]
When the control panel detects a tamper or wire fault on a zone or on an expansion module, the control panel can generate an alarm and/or trouble, as shown in
the table below.
Partition 1: [3118] Partition 3: [3318] Partition 5: [3518] Partition 7: [3718]
Partition 2: [3218] Partition 4: [3418] Partition 6: [3618] Partition 8: [3818]
[5] [6] Description
OFF OFF
Disabled (default):
Displays zone open on the keypads, but will not generate an alarm or trouble.
Not permitted on UL systems.
OFF ON
Generates Trouble Only (when armed or disarmed):
The control panel displays Zone Fault in the Trouble Display and transmits the
defined report code (see
section on page 40).
ON OFF
When disarmed: Generates Trouble Only
The control panel displays Zone Fault in the Trouble Display and transmits the
defined report code (see
section on page 40).
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (see
section on page 24).
ON ON
When disarmed: Generates Audible Alarm
The control panel displays Zone Fault in the Trouble Display, transmits the
defined report code (see
section on page 40), and generates an audible
alarm.
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (see
section on page 24).