EVOHD+ Installation Guide
Re-Address Scanning (TM50/TM70 Keypads only)
This option will scan all addresses on the combus. If any missing modules are detected (e.g., detector removed from combus), the control panel will quarantine
them. To permanently remove the module’s serial number from the system, refer to the Quarantine Modules section.
To scan modules on your EVOHD+ panel:
1. Press and hold the
MENU button and then enter your installer code.
2. Select M
ANAGE BUS MODULES.
3. Select R
E-ADDRESS BUS MODULES.
4. Press Y
ES to begin the scan process or NO to cancel.
5. The system will then begin scanning the modules on the bus, this will take a few minutes. Please note, modules will not be deleted from the system.
6. Once the scan is complete, press OK to return to the Main menu.
Quarantine Modules (TM50/TM70 Keypads only)
This option allows you to permanently delete any missing modules from your system.
To quarantine modules on your EVOHD+ panel:
1. Press and hold the
MENU button and then enter your installer code.
2. Select the
MANAGE BUS MODULES button.
3. Select the
MANAGE QUARANTINE MODULES.
4. From the quarantine Modules list, select the modules that you wish to remove from the system.
5. Select the D
ELETE button. A confirmation screen will appear. Press DELETE to remove the modules from the system or NO to cancel the deletion process.
6. Once the modules have been successful deleted, you will be returned to the Manage Bus Modules menu.
Serial Number Viewing
SECTION [4000]
Enter section [4000] to view the serial number of the control panel and all the modules on the Digiplex bus. The firmware version of some modules will be displayed
as well (e.g. (XXXXXXXX) VXX.XX).
For LCD Keypads: The keypad will display the control panel’s serial number. Use the [
] and [] keys to scroll.
Power Save Mode
SECTION [3033]: OPTIONS [4]
(default = enabled) When enabled and the control panel is running on the backup battery, the control panel can set all keypads into Power Save Mode. The
keypad's backlight and LEDs are disabled until a key is pressed, an alarm occurs or an Entry Delay is triggered.
Auto Trouble Shutdown
SECTION [3021]
(default = 00) If a trouble occurs more than the number programmed, the control panel stops reporting the trouble. Enter a value between 01 and 15, (00 = disabled).
Each trouble has its own counter that is reset at midnight.
No AC Fail Display
SECTION [3030]: OPTION [6]
(default = disabled) When enabled, the control panel will not display the AC Failure as a trouble. When an AC Failure occurs with this option enabled:
• the AC LED will extinguish
• the AC Failure report code will be reported.
• the trouble will not appear in the Trouble Display
• the keypad will not beep to indicate the trouble
Multiple Action Feature
SECTION [3033]: OPTION [1]
(default = disabled) When enabled, users will remain in the User Menu after entering their access code. With option
[1] off, the control panel will exit the User Menu
after every action.