70
EVOHD+ Installation Guide
Appendix 1: Automatic Report Code List
System Event
Default Contact ID Report Code
(when using sections [4032] to [4037])
Default SIA Report Code
(when using sections [4032] to [4037])
Arming with master code (##) 3 4A1 Close by user CL Closing report
Arming with user code (##) 3 4A1 Close by user CL Closing report
Arming with keyswitch (##) 3 4A9 Keyswitch close CS Closing keyswitch
Auto arming 3 4A3 Automatic close CA Automatic closing
Arm with PC software 3 4A7 Remote arm/disarm CQ Remote arming
Late to close 3 452 Late to close OT Late to close
No movement 3 452 Late to close NA No movement arming
Partial arming 1 456 Partial arm CG Close area
Quick arming 3 4A8 Quick arm CL Closing report
Remote arm (voice) 3 4A7 Remote arm CQ Arm with voice module
Delinquency closing 1 654 System inactivity CD System inactivity
Disarm with master code (##) 1 4A1 Open by user OP Opening report
Disarm with user code (##) 1 4A1 Open by user OP Opening report
Disarm with keyswitch (##) 1 4A9 Keyswitch open OS Opening keyswitch
Disarm after alarm with master code (##) 1 4A1 Open by user OP Opening report
Disarm after alarm with user code (##) 1 4A1 Open by user OP Opening report
Disarm after alarm with keyswitch (##) 1 4A9 Keyswitch open OS Opening keyswitch
Cancel alarm with master code (##) 1 4A6 Cancel OR Disarm from alarm
Cancel alarm with user code (##) 1 4A6 Cancel OR Disarm from alarm
Cancel alarm with keyswitch (##) 1 4A6 Cancel OS Opening keyswitch
Auto arming cancellation 1 464 Auto-arm time extended CE Closing extend
Cancel alarm with PC software 1 4A6 Cancel OR Disarm from alarm
Voice disarm 1 4A7 Remote arm/disarm OQ Remote disarming
Disarm with PC software 1 4A7 Remote arm/disarm OQ Remote disarming
Disarm after an alarm with PC software 1 4A7 Remote arm/disarm OQ Remote disarming
Quick disarm 1 4A8 Quick disarm OP Opening report
Zone Bypassed (##) 1 57A Zone bypass UB Untyped zone bypass
Zone alarm (##) 1 13A Burglary alarm BA Burglary alarm
Fire alarm (##) 1 11A Fire alarm FA Fire alarm
Early to Disarm by User 1 451 Early to open OK Early to open
Late to Disarm by User 1 452 Late to open OJ Late to open
Failed to arm 1 454 Failed to close CI Failed to close
Zone alarm restore (##) 3 13A Burglary alarm restore BH Burglary alarm restore
Fire alarm restore (##) 3 11A Fire alarm restore FH Fire alarm restore
24-hr Gas alarm (##) 1 13A Burglary alarm GA Gas alarm
24-hr Heat alarm (##) 1 13A Burglary alarm KA Heat alarm
24-hr Water alarm (##) 1 13A Burglary alarm WA Water alarm
24-hr Freeze alarm (##) 1 13A Burglary alarm ZA Freeze alarm
24-hr Gas alarm restore (##) 3 13A Burglary alarm restore GR Gas alarm restore
24-hr Heat alarm restore (##) 3 13A Burglary alarm restore KR Heat alarm restore
24-hr Water alarm restore (##) 3 13A Burglary alarm restore WR Water alarm restore
24-hr Freeze alarm restore (##) 3 13A Burglary alarm restore ZR Freeze alarm restore
Panic 1: emergency 1 12A Panic alarm PA Panic alarm
Panic 2: medical 1 1AA Medical alarm MA Medical alarm
Panic 3: fire 1 115 Pull station FA Fire alarm
Recent closing 3 459 Recent close CR Recent closing
Police code 1 139 Burglary alarm BM Burglary alarm