EVOHD+ Installation Guide
71
Global zone shutdown 1 574 Group bypass CG Close area
Duress alarm 1 121 Duress HA Hold-up alarm
Zone shutdown (##) 1 57A Zone bypass UB Untyped zone bypass
Zone tampered (##) 1 144 Sensor tamper TA Tamper alarm
Zone tamper restore (##) 3 144 Sensor tamper restore TR Tamper restoral
Keypad lockout 1 421 Access denied JA User code tamper
AC failure 1 3A1 AC loss AT AC trouble
Battery failure 1 3A9 Battery test failure YT System battery trouble
Auxiliary supply trouble 1 3AA System trouble YP Power supply trouble
Bell output current limit 1 321 Bell 1 YA Bell fault
Bell absent 1 321 Bell 1 YA Bell fault
Clock lost 1 626 Time/date inaccurate JT Time changed
Fire loop trouble 1 373 Fire trouble FT Fire trouble
Panel tamper 1 144 Sensor tamper TA Tamper alarm
TLM trouble restore 3 351 Telco 1 fault restore LR Phone line restoral
AC failure restore 3 3A1 AC loss restore AR AC restoral
Battery failure restore 3 3A9 Battery test restore YR System battery restoral
Auxiliary supply trouble restore 3 3AA System trouble restore YQ Power supply restored
Bell output current limit restore 3 321 Bell 1 restore YH Bell restored
Bell absent restore 3 321 Bell 1 restore YH Bell restored
Clock programmed 3 625 Time/date reset JT Time changed
Fire loop trouble restore 3 373 Fire trouble restore FJ Fire trouble restore
Panel tamper restore 1 373 Sensor tamper restore FT Tamper restoral
Combus fault 1 333 Expansion module failure ET Expansion trouble
Module tamper 1 145 Expansion module tamper TA Tamper alarm
Module ROM_RAM_error 1 3A4 ROM checksum bad YF Parameter checksum fail
Module TLM trouble 1 352 Telco 2 fault LT Phone line trouble
Module fail to communicate to monitoring station 1 354 Fail to communicate YC Communication fails
Printer fault 1 336 Local printer failure VT Printer trouble
Module AC failure 1 3A1 AC loss AT AC trouble
Module battery failure 1 3A9 Battery test failure YT System battery trouble
Module auxiliary supply trouble 1 3AA System trouble YP Power supply trouble
Module IP receiver supervision - - - -
Module IP receiver fail to communicate - - - -
Module IP receiver unregistered - - - -
Direct light - - - -
Module Rf Interference 1 344 RF receiver Jam XQ RF Jamming
Module low voltage - - - -
Module self-test error - - - -
Module LAN trouble - - - -
Module WAN trouble - - - -
Combus fault restore 3 333 Expansion module failure restore ER Expansion restoral
Panel tamper restore 3144 Sensor tamper restore TR Tamper Restoral
Module tamper restore 3 145 Expansion module tamper restore TR Tamper restoral
Module ROM_RAM_error restore 3 3A4 ROM checksum bad restore YG Parameter changed
Module TLM restore 3 352 Telco 2 fault restore LR Phone line restoral
Early to arm by user 3 451 Early to close CK Early to close
Late to arm by user 3 452 Late to close CJ Late to close
Zone excluded on Force arming 1 57A Zone bypass XW Zone forced
System Event
Default Contact ID Report Code
(when using sections [4032] to [4037])
Default SIA Report Code
(when using sections [4032] to [4037])

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox EVOHD+ and is the answer not in the manual?

Paradox EVOHD+ Specifications

General IconGeneral
BrandParadox
ModelEVOHD+
CategorySecurity System
LanguageEnglish

Related product manuals