62
EVOHD+ Installation Guide
Partition Assignment
SECTIONS [1002] TO [1999]: ASSIGN AREA SCREEN, OPTIONS [1] TO [8]
Each of the 998 user access codes can be assigned to one or more partitions. Users can only arm, disarm and view the status of the partitions assigned to their user
access codes. Select one or more of the partitions for each user access code as shown in Figure 18 on page 61.
NOTE: If no partition assignment is selected, the user access code will only be able to activate PGMs.
The default setting depends on the programming user’s assigned partitions. For example, when a user (with master feature) that is assigned to partitions 1 and 2
programs a user code, partitions 1 and 2 will be the default setting for the new user.
Access Control
SECTIONS [1002] TO [1999]
In addition to the user access code options, the following options can be programmed when Access Control is enabled: Access Level, Schedule, Access Options and
Access Card. For details on Access Control, see page 64.
NOTE: The System Master Code and user access codes with the Full Master feature enabled can also program the Access Level, Schedule, Access User Options, and
Access Card using another method for programming.
WARNING: The System Master Code has access to all doors all the time. Only the card’s serial number and the choice of arming method can be changed. If
the other options are changed, the System Master Code will revert to its original programming.
Access Level Assignment
SECTIONS [1002] TO [1999]: LEVEL + SCHEDULE SCREEN
User access codes can only open the doors included in their assigned Access Level (see section on page 65). In the first set of brackets, enter the two-digit Access
Level number (00 to 15, 00 = unrestricted) to be assigned to that user access code.
Schedule Assignment
SECTIONS [1002] TO [1999]: LEVEL + SCHEDULE SCREEN
Schedules determine the hours, days and holidays that user access codes can open the doors in their assigned Access Level (see section ). In the second set of
brackets, enter the two-digit Primary Schedule number (00 to 15, 00 = unrestricted) to be assigned to that user access code.
[1] [2]
OFF OFF
Master disabled User cannot create or modify other user access codes.
ON OFF
Master enabled
User can create new user access codes with default options only, can
program PINs and User Labels.
ON ON
Full Master enabled
User can create and modify user access codes and program the User Options,
Partition Assignment (can assign only the partitions the Master Code has
access to), Access Control features, PINs and User Labels.
[3] Duress
A Duress enabled user access code can arm or disarm the partition and can
immediately transmit a silent alarm to the monitoring station.
[4] Bypass User can program bypass entries.
[5] Arm Only User can arm assigned partitions, but cannot disarm.
[6] Stay or Instant Arm User can Stay arm or Instant arm assigned partitions.
[7] Force Arm User can Force arm assigned partitions
[8] User Menu Access
Option [8] ON = User can access all its assigned partitions, regardless of the
keypad’s partition assignment.
Option [8] OFF = User can only access the partitions assigned to both itself
and the keypad.