EVOHD+ Installation Guide
47
Recent Close Delay
(default = 000) If an alarm is generated within the programmed period after arming the partition, the control panel will transmit the Recent Close report code
programmed into section [3933]. Enter any value between 001 and 255 to determine Recent Close Delay in seconds.
Power Failure Report Delay
SECTION [3058]
(default = 030) The control panel will delay the transmission of the AC Failure report code programmed into section [3941] by the period programmed into section
[3058]. Enter any value between 001 and 255 to determine Power Failure Report Delay in minutes.
Power Failure Restore Report Delay
SECTION [3060]
(default = 030) The control panel will delay the transmission of the AC Failure Restore report code programmed into section [3972] by the period programmed into
section [3060]. Enter any value between 001 and 255 to determine Power Failure Restore Report Delay in minutes.
Auto Test Report
SECTION [3037]: OPTIONS [3] AND [4] AND
SECTIONS [3040], [3041], [3042] AND [3043]
The control panel can transmit the test report code programmed into section
[3902] every hour or after a period of time.
Partition 1: [3109] Partition 3: [3309] Partition 5: [3509] Partition 7: [3709]
Partition 2: [3209] Partition 4: [3409] Partition 6: [3609] Partition 8: [3809]
OFF OFF
Auto Test
Report Period
(default)
After the number programmed (000 to 255 days, default =
000) in section [3040], the control panel transmits a report
code at the time (00:00 to 23:59, default = 00:00)
programmed in section [3041].
OFF ON
Timed Test
Transmission
when Armed/
Disarmed
When disarmed: The control panel transmits the code at
regular intervals. Program the number of minutes (000 to 255,
default = 060) between transmissions in section [3043].
When armed: The control panel transmits the test report
code at regular intervals. Program the number of minutes
(000 to 255, default = 005) between each transmission in
section [3042].
ON OFF
Hourly Test
Transmission
The control panel will transmit the test report code every
hour on the minute value programmed in section [3041] (the
last two digits). Note that the first two digits of section [3041]
will be ignored.
ON ON
Timed and
Hourly Test
Transmission
The test report code will be transmitted when any of the
conditions of the second and third options listed above
(options [3] = OFF and [4] = ON / options [3] = ON and [4] =
OFF) are met.