Operating the Drive 
Page 7-10  890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D 
8 
9 
10 
11 
 
B 
C 
D 
1 
2 
3 
4 
5 
6 
7 
E 
Coast to Stop 
Set the SETUP::SEQ & REF::REFERENCE STOP::RUN STOP MODE parameter to COAST. 
In this mode the DECEL TIME ramp and the STOP TIME ramp are both ignored. Thus the SPEED 
DEMAND changes immediately to 0% as soon as the Stop command is given. The power stack is also 
immediately disabled at this time, causing the load to coast. 
POWER CIRCUIT DISABLED
SPEED DEMAND
REMOTE SETPOINT
Speed 0%
RUN input
 
Figure 7.6  Coast to Stop with a Remote Reference