890CS & 890CD Common Bus Units 
Page 4-34  890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D 
8 
9 
10 
11 
 
B 
C 
D 
1 
2 
3 
4 
5 
6 
7 
E 
4.1: Power-up with 24V DC 
You must provide an external 0V and +24V DC 
(±10%) control supply. Each unit, including the 
Common Bus Supply, can draw 2A, so for 
example: 3 units = 6A. 
Connect 24V DC to terminal X01/01 or 
X02/02, and 0V (24V) to terminal X01/03 or 
X01/04 on the 890CS Common Bus Supply. 
The units are protected against reversal of this 
24V DC supply. 
Use the spare X01 terminals to daisy-chain the 
control supply to terminal X13 on the 890CD 
Common Bus Drive(s) in the system. 
The diagram shows the control supply daisy-
chained between the 890 Supply and Drive 
units. 
IMPORTANT  This Control Supply will power the units for 
configuration purposes. It is not required by 
the 890CD Common Bus Drive when the DC 
link is present, but can be left connected. It is 
always required by the 890CS Common Bus 
Supply. 
24V DC
24V DC
890CS
Supply
890CD
Drives