PHASE TUNING 
SETUP::PHASE CONTROL::PHASE TUNING 
The Tuning function block provides a means of injecting a speed offset or a phase offset in a selected wave form to assist the 
tuning of the speed and phase loops. It would be unusual for both tests to be active together. 
Parameter Descriptions 
ENABLE PHASE 
PREF: 111.04  Default: FALSE  Range: FALSE / TRUE 
Activates a test function to add a test signal to the position demand (phase offset). 
ENABLE SPEED 
PREF: 111.02  Default: FALSE  Range: FALSE / TRUE 
Activates a test function to add a test signal to the speed demand (speed offset). 
REFERENCE TYPE 
PREF: 111.08   Default: 0  Range: See below 
Type of tuning reference, either square, sine, or triangular wave. 
Enumerated Value : Type 
0 : SQUARE     
1 : SINUSOIDAL  
2 : TRIANGULAR   
SPEED AMPLITUDE 
PREF: 111.09  Default: 0.1000 rev/s  Range: 0.0000 to 100.0000 
rev/s 
This parameter sets the amplitude of the test signal. The signal is symmetric. (i.e. for an amplitude of 1 % the test signal varies 
by +/- 1.0 %). In speed test mode, the unit of this parameter are load speed, in position test mode, the unit is percent of 1 load 
revolution. 
POS'N AMPLITUDE 
PREF: 111.16  Default: 1.0000 deg  Range: 0.0000 to 100.0000 deg 
This parameter sets the amplitude of the test signal. The signal is symmetric. (i.e. for an amplitude of 1 % the test signal varies 
by +/- 1.0 %). In speed test mode, the unit of this parameter are load speed, in position test mode, the unit is percent of 1 load 
revolution.