Technical Specifications 
Page E-14  890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D 
8 
9 
10 
11 
 
B 
C 
D 
1 
2 
3 
4 
5 
6 
7 
E 
Electrical Ratings:  890CD Frame B, 380-500V  
Input currents listed at 560V DC and 650V DC assuming total source impedance of 800μH. Motor power, input current and 
output current must not be exceeded under steady state operating conditions. 
Model Number 
890CD/5/0006B 890CD/5/0010B 890CD/5/0012B 
Nominal Supply Voltage 
560Vdc  650-705Vdc  560Vdc  650-705Vdc 560Vdc  650-705Vdc 
Motor Power    2.2kW  3Hp 4kW 5Hp 5.5kW 7.5Hp 
Internal Fuse Rating   A 40  40  40  40  40  40 
 
Vector Mode 
Input Current (DC, rms)  A 8.6  7.2  14.1 11.3 16.8 16.6 
Output Current @ 3kHz (note 1)  A 6  5  10  8  12  12 
Power Loss @ 3kHz   W 95  90  125  115  145  150 
Output Current @ 6kHz (note 2)  A 5.0  4.1  8.3  6.5  12  11.7 
Power Loss @ 6kHz   W 95  90  125  115  165  170 
Output Overload Motoring  150% overload for 60 seconds 
 
Servo Mode 
Input Current (DC, rms) (note 3) A 7.0  7.1  9.8  10.0 14.0 13.9 
Output Current @ 4kHz   A 4  4  6  6  9  9 
Power Loss @ 4kHz   W 85  85  100  125  130  130 
Output Current @ 8kHz (note 2)  A 3.3  3.2  4.8  4.7  9  8.1 
Power Loss @ 8kHz   W 85  85  100  125  145  140 
Output Overload Motoring  200% overload for 4 seconds 
Notes: 
1) Up to the highest supply voltage that maintains shaft power less than the product power rating, for a typical induction motor. Derated for operation above this supply voltage. 
2) Products take less input current when operated in these modes, than stated.
 
3) Based on a permanent-magnet motor with efficiency 90% and power factor 0.9.