Keypad Menus
Page 9-28 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
QUICK SETUP MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF 6511/6901
Display
Description Range Default
3.03
AIN 3 TYPE
Selects input range for Analog Input 3. 0 = -10..+10 V
1 = 0..+10 V
2 = 0..20 mA
3 = 4..20 mA
0
4.03
AIN 4 TYPE
Selects input range for Analog Input 4. 0 = -10..+10 V
1 = 0..+10 V
2 = 0..20 mA
3 = 4..20 mA
0
97.01
DISABLE TRIPS
Indicates which trips have been disabled. Not
all trips may be disabled, the DISABLED TRIPS
mask is ignored for trips that cannot be
disabled. Refer to Chapter 10.
0000 to FFFF 0700
97.02
DISABLE TRIPS+
Indicates which trips have been disabled. Not
all trips may be disabled, the DISABLED TRIPS
mask is ignored for trips that cannot be
disabled. Refer to Chapter 10.
0000 to FFFF 0840
31.01
VIEW LEVEL
Selects the menu to be displayed by the
keypad.
0 : OPERATOR
1 : BASIC
2 : ADVANCED
1