Parameter Descriptions 
SPEED FBK RPM 
PREF: 70.04  Default: —.xx  rpm  Range: —.xx  rpm 
This parameter changes according to the CONTROL MODE (MOTOR DATA function block): 
•  In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per minute as 
calculated from the speed feedback device. 
•  In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per 
minute. 
•  In VOLTS/Hz mode the parameter shows motor synchronous speed in rpm. 
SPEED FBK REV/S 
PREF: 70.05  Default: —.xx  rev/s  Range: —.xx  rev/s 
This parameter changes according to the CONTROL MODE (MOTOR DATA function block): 
•  In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per second as 
calculated from the motor speed feedback. 
•  In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per 
second. 
•  In VOLTS / Hz mode, the parameter shows the motor synchronous speed in revolutions per second. 
SPEED FBK % 
PREF: 70.06  Default: —.xx  %  Range: —.xx  % 
This parameter changes according to the CONTROL MODE (MOTOR DATA function block): 
•  In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft as a percentage of the user 
maximum speed setting (MAX SPEED in the REFERENCE function block) as calculated from the motor speed feedback. 
•  In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft as a percentage of 
the user maximum speed setting (MAX SPEED in the REFERENCE function block). 
•  In VOLTS / Hz mode, the parameter shows the electrical drive output frequency as a percentage of the user maximum 
speed setting (MAX SPEED in the REFERENCE function block).