EasyManua.ls Logo

Parker 890CD - Page 531

Parker 890CD
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page D-187
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
97.05 ACTIVE TRIPS TRIPS STATUS WORD 0000 to FFFF 0000 ro Output
97.06 ACTIVE TRIPS+ TRIPS STATUS WORD 0000 to FFFF 0000 ro Output
97.07 WARNINGS TRIPS STATUS WORD 0000 to FFFF 0000 ro Output
97.08 WARNINGS+ TRIPS STATUS WORD 0000 to FFFF 1000 ro Output
97.09 FIRST TRIP TRIPS STATUS ENUM As PREF 96.01 NO TRIP ro Output
98.01 INVERT THERMIST I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw
98.02 INVERT ENC TRIP I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw
98.03 INPUT 1 BREAK I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw
98.04 INPUT 2 BREAK I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE rw
98.05 THERMISTOR I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
98.06 ENCODER I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
98.07 EXTERNAL TRIP I/O TRIPS BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
98.08 EXT TRIP MODE I/O TRIPS ENUM 0 : TRIP
1 : COAST
2 : DISABLED
DISABLED rw
99.01 ENABLE DYNAMIC BRAKING BOOL 0 : FALSE
1 : TRUE
TRUE rw
99.03 BRAKE RESISTANCE DYNAMIC BRAKING REAL 0.01 to 300.00 Ohm 100.00 Ohm rw 2
99.04 BRAKE POWER DYNAMIC BRAKING REAL 0.1 to 510.0 kW 0.1 kW rw 2
99.05 1SEC OVER RATING DYNAMIC BRAKING REAL 1 to 40 25 rw 2
99.06 BRAKING DYNAMIC BRAKING BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
99.07 INT DB RESISTOR DYNAMIC BRAKING BOOL 0 : FALSE
1 : TRUE
TRUE rw 3