COMPAX CANopen
Status S6
34
6.10 Diagnostics
6.10.1 Status S6
Temperature of the power output stage.
Object Description
Index
0x2011
Symbol
S6
Length
2
Min
0
Object code
Variable
Max
0xFFFF
Data type
Unsigned16
Access rights
read
PDO mapping
no
Data Description
Unit
degrees Celsius
Resolution
1 0.1°C
6.10.2 Status S9
Number of axis motion cycles.
Object Description
Index
0x2013
Symbol
S9
Length
4
Min
0x00000000
Object code
Variable
Max
0xFFFFFFFF
Data type
Unsigned32
Access rights
read
PDO mapping
no
6.10.3 Status S10
COMPAX operating hours
Object Description
Index
0x2014
Symbol
S10
Length
4
Min
0x00000000
Object code
Variable
Max
0xFFFFFFFF
Data type
Unsigned32
Access rights
read
PDO mapping
no
Data Description
Unit
Hours
Resolution
1 0.1 h